Asset
|
Description
|
Property Type
|
Recovery Period
|
|
Awnings & Canopies
|
Readily removable overhang or covering, often of canvas or plastic, used to provide
shade or cover over a storefront, a window, or a door; or used inside a structure
to identify a particular department or selling area. Also includes canopies
designed to protect employees and gasoline fueling equipment from weather conditions
and to act as advertising displays that are anchored with bolts and are not attached
to buildings or other structures. Does not include permanent canopies that
are an integral part of a building’s structural shell, such as porte-cochere (covered
entrances for vehicle drive-up) and porticos (covered porches), or over docks.
See also Concrete Foundations & Footings, Loading Docks, and Signs.
|
1245
|
57.0 Distributive Trades and Services --
5 Years
|
|
Bollards & Guardrails
|
Bollards (heavy steel posts generally filled with concrete) and Guardrails mounted
in a concrete foundation or sturdily affixed to the ground so as to create a protective
barrier around areas of the building vulnerable to vehicle traffic such as Service
Bay doors, glass storefront partitions, doors, door frames, HVAC components, building
corners, etc. Bollards and Guardrails can be located inside or outside the
building are permanently attached and are intended to be permanent. (Placement to
protect the building).
|
1250
|
Building or Building Component –
39 Years
|
|
Bollards (heavy steel posts generally filled with concrete) and Guardrails mounted
in the ground or concrete to protect machinery and equipment from vehicular damage,
or to prevent vehicles from trespassing onto specific areas. Placement to
protect land improvements and non-building items such as signs, sign poles, flagpoles,
trees, as well as inventories of autos and trucks. Bollard and Guardrails are permanently
attached and intended to be permanent.
Note* asset class 00.3 Land improvements includes both section 1245 and 1250
property per Rev. Proc. 87-56.
|
See Note*
|
00.3 Land Improvements –
15 Years
|
|
Bollards & Guardrails
|
Bollards (heavy steel posts) and Guardrails, not permanently attached and not intended
to be permanent, placed near machinery and equipment inside buildings that can be
damaged by vehicular traffic. Bollards and Guardrails withstand vehicular
impact and protect personal property items such as: forklift recharging stations,
service write-up station, hazardous material storage racks, service department air
compressors, etc.
|
1245
|
57.0 Distributive Trades and Services --
5 Years
|
|
Cabinetry
|
Includes cabinets and counters constructed or installed within buildings that relate
to the general operation and maintenance of the building. For example, cabinets
and counters used to house or enclose electrical equipment, plumbing components,
sinks, fire protection systems, and other structural elements of a building which
are designed to remain in place. Includes counters and cabinets in restrooms,
Employee Break Areas, Employee Coffee Bars, and Office Areas.
See also Restroom Accessories.
|
1250
|
Building or Building Component –
39 Years
|
|
Includes cabinets and counters related to the retail activity and not related to
the operation and maintenance of the building. For example: retail counters
and cabinets, display shelving and cabinets, customer reception counter, Customer
Lounge Area cabinets and counters, Sales Area cabinets
and counters, parts counters, etc. See also Retail Fixtures and Office
Furniture.
|
1245
|
57.0 Distributive Trades and Services --
5 Years
|
|
Computers
|
Processors (CPU), direct access storage device (DASD), tape drives, desktop and
laptop computers, CRT, terminals, monitors, printers, and other peripheral equipment.
Excludes Point of Sale (POS) systems and computers that are an integral part of
other equipment (e.g. fire detection, heating, cooling, or energy management systems,
etc.). See also Point of Sale (POS) Systems.
|
1245
|
00.12 Information Systems –
5 Years
|
|
Concrete Foundations & Footings
|
Foundations and footings necessary for the proper setting of the building.
Excavation and backfill for building foundations. Excavation and backfill
for special equipment foundations where contained within the footprint of the building.
Includes formwork, reinforcement, concrete block, and pre-cast or cast-in-place
work.
|
1250
|
Building or Building Component –
39 Years
|
|
Foundations or footings for signs, light poles, and other land improvements (except
buildings). Includes excavation, backfill, formwork, reinforcement,
concrete block, and pre-cast or cast-in-place work. Note* asset class
00.3 Land improvements includes both section 1245 and 1250 property per Rev. Proc.
87-56.
|
See Note*
|
00.3 Land Improvements –
15 Years
|
|
Concrete Foundations & Footings
|
A foundation, pad, or footing for machinery or equipment that is so specially designed
that it is in essence a part of the machinery or equipment. Any function as
a building component must be strictly incidental to the function as an essential
part of the item of machinery or equipment that necessitated the special design
of the foundation. Increased thickness of the building’s slab alone is not
sufficient to show that the foundation, pad, or footing is so specially designed
that it is in essence a part of the machinery or equipment it supports. Excavation
and backfill are not included where the foundation, pad, or footing is contained
within the footprint of the building. Includes formwork, reinforcement, concrete
block, and pre-cast or cast-in-place work.
|
1245
|
57.0 Distributive Trades and Services –
5 Years
|
|
Data Handling Equipment
|
Includes adding and accounting machines, calculators, copiers, and duplicating machines.
Excludes computers and computer peripheral equipment.
|
1245
|
00.13 Data Handling Equipment, except Computers –
5 Years
|
|
Doors
|
Interior and exterior doors, regardless of decoration, including but not limited
to, double opening doors, fire doors and fire containment safety doors, overhead
and roll-up doors, revolving doors, roll-up or sliding wire mesh or steel grills,
Service Bay doors, and related door hardware (such as doorknobs,
closers, kick plates, hinges, locks, automatic openers, computerized door locks,
etc.). See also Millwork.
|
1250
|
Building or Building Component –
39 Years
|
|
Special lightweight, double action doors installed to prevent accidents in a heavily
trafficked area. For example, flexible doors, or clear or strip curtains used
between stock and selling areas.
|
1245
|
57.0 Distributive Trades and Services –
5 Years
|
|
Electrical
|
Includes all components of the building electrical system used in the operation
or maintenance of the building or necessary to provide general building services
such as electrical outlets of general applicability and accessibility, lighting,
heating, ventilation, air conditioning, and electrical wiring. Includes but
is not limited to general purpose outlets connected to copy machines, fax machines,
personal computers, and general purpose outlets in the Break Rooms, Coffee Rooms,
Lounges, etc.
|
1250
|
Building or Building Component –
39 Years
|
|
Electrical
|
Includes electrical outlets specifically associated to a particular item of machinery
or equipment located in the Service Department, Body Shop, and Showroom.
Special electrical connections which are necessary to and used directly with a specific
item of machinery or equipment or connections between specific items of individual
machinery or equipment; such as dedicated electrical outlets, wiring, conduit, and
circuit breakers by which machinery and equipment is connected to the electrical
distribution system. Does not include electrical outlets of general applicability
and accessibility. See Chapter 5 of the Cost Segregation Audit Techniques
Guide for allocation examples.
Examples include: Dedicated electrical service to lifts, jacks and Service
Bay equipment; paint booths; car washes; oil change stations; frame straightening
equipment and Body Shop equipment. Also includes dedicated
electrical to Customer Areas, such as suspended television monitors.
|
1245
|
57.0 Distributive Trades and Services --
5 Years
|
|
Elevators and Escalators
|
Elevators and escalators, which include handrails and smoke baffles, are permanently
affixed to the building and intended to remain in place. They relate to the
operation or maintenance of the building and are structural components.
Includes elevators to move autos in multi-story dealerships.
|
1250
|
Building or Building Component –
39 Years
|
|
Energy Management Systems
|
Energy management systems control all energy-using systems in a building, automatically
checking occupancy schedules, reading temperatures, and re-circuiting light levels,
causing all heating, cooling and lighting equipment to operate so as to minimize
energy costs. Includes, for example, detection devices such as smoke, motion
and infrared devices, photocells, foil and contact switches, pressure switches,
proximity alarms, sensors, alarm transmitting controls, data gathering panels, demand
controllers, thermostats, computer controls, outside air economizers, occupancy
sensors, electronic ballasts, and all related wiring and conduit. May also
provide for fire and burglary protection.
|
1250
|
Building or Building Component –
39 Years
|
|
Exit Signs
|
Signs posted along exit routes within buildings that indicate the direction of travel
to the nearest exit. These signs typically read "EXIT" and may have distinctive
colors, illumination, or arrows indicating the direction to the exit.
|
1250
|
Building or Building Component – 39 Years
|
|
Fire Protection & Alarm Systems
|
Includes sensing devices, computer controls, sprinkler heads, piping or plumbing,
pumps, visual and audible alarms, alarm control panels, heat and smoke detection
devices, fire escapes, fire doors, emergency lighting and signage, and wall mounted
fire extinguishers necessary for the protection of the building.
|
1250
|
Building or Building Component –
39 Years
|
|
Fire Protection Equipment
|
Includes special fire detection or suppression systems directly associated with
a piece of equipment and designed and used for protection against a particular hazard
created by the business activity (such as in the Body Shop).
|
1245
|
57.0 Distributive Trades and Services --
5 Years
|
|
Floor Coverings
|
Floor covering affixed with permanent adhesive, nailed, or screwed in place.
Examples include ceramic or quarry tile, marble, paving brick, and other coverings
cemented, mudded, or grouted to the floor; epoxy or sealers; and wood flooring.
|
1250
|
Building or Building Component –
39 Years
|
|
Floor covering that is installed by means of strippable adhesives. For the
auto dealership industry, all vinyl composition tile (VCT), sheet vinyl, and carpeting
will be treated as not permanently attached and not intended to be permanent.
|
1245
|
57.0 Distributive Trades and Services --
5 Years
|
|
Floors
|
Includes concrete slabs and other floor systems. Floors include special treatments
applied to or otherwise a permanent part of the floor. For example, reflective
flooring, express lube and reconditioning area floors, and epoxy floor paint or
sealant applied directly to the concrete slab to keep a sealed, water and oil resistant,
easy-to-clean surface. See also Floor Coverings.
|
1250
|
Building or Building Component –
39 Years
|
|
Floor Pits & Trenches
|
Work areas built at a lower level than the garage floor to allow technicians to
stand beneath the vehicles while working. These floor pits allow the technician
to service a vehicle from below (for example, to change automotive oil, radiator
and transmission fluids). Work areas include pits and trenches with concrete
floors and walls with overhead access to vehicles. Some of these floor pits
resemble full basements allowing multiple technicians access to vehicles above.
|
1250
|
Building or Building Component –
39 Years
|
|
Equipment included in the floor pits & trenches such as lifts, trays, and piping
for supply fluid systems; waste fluid recovery and containment systems; and automotive
fluid waste tanks.
|
1245
|
57.0 Distributive Trades and Services --
5 Years
|
|
Heating, Ventilating & Air Conditioning (HVAC)
|
Includes all components of a central heating, ventilating and air conditioning system
not specifically identified elsewhere. HVAC systems that are installed not only
to meet the temperature and humidity requirements of machinery, but are also installed
for additional significant purposes, such as customer comfort and ventilation, are
building components.
|
1250
|
Building or Building Component –
39 Years
|
|
Only separate HVAC units that meet the sole justification test are included (i.e.,
machinery the sole justification for the installation of which is the fact that
such machinery is required to meet temperature or humidity requirements which are
essential for the operation of other machinery or the processing of materials or
paint). For example, special ventilation for paint booths; Body Shop
and Service Area exhaust removal systems. Allocation of HVAC
is not appropriate.
|
1245
|
57.0 Distributive Trades and Services --
5 Years
|
|
Inventory Display
Equipment
|
Includes inventory displays that are permanently added to the land. Examples
include concrete ramps and pedestals, and exterior “turntable” displays that are
permanently affixed, etc.
Note* asset class 00.3 Land improvements includes both section 1245 and 1250
property per Rev. Proc. 87-56.
|
See Note*
|
00.3 Land Improvements –
15 Years
|
|
Includes inventory displays that are not permanently added to the land and intended
to be moved. Examples include metal ramps, portable “turntable” displays,
etc.
|
1245
|
57.0 Distributive Trades and Services --
5 Years
|
|
Landscaping & Shrubbery
|
Landscaping that will not be replaced contemporaneously with a related depreciable
asset or that will not be destroyed when the related depreciable asset is replaced.
Examples include landscaping, shrubbery, trees, plant foliage, or sod placed around
the perimeter of the tract of land.
|
|
Land
|
|
Landscaping that will be replaced contemporaneously with a related depreciable asset
or that will be destroyed when the related depreciable asset is replaced.
Examples include depreciable landscaping, shrubbery, trees, plant foliage, or sod
placed around the parking lot in outdoor Sales Area. Includes
associated irrigation systems (sprinkler systems).
Note* asset class 00.3 Land improvements includes both section 1245 and 1250
property per Rev. Proc. 87-56.
|
See Note*
|
00.3 Land Improvements –
15 Years
|
|
Light Fixtures - Interior
|
Includes lighting such as recessed and lay-in lighting, night lighting, and exit
lighting, as well as decorative lighting fixtures that provide substantially all
the artificial illumination in the building or along building walkways. For
emergency and exit lighting, see Fire Protection & Alarm Systems.
|
1250
|
Building or Building Component –
39 Years
|
|
Special display lighting specifically for highlighting automobiles in the Showroom,
or highlighting displays of merchandise, decorative lighting, and specific task
lighting in the service area. Decorative light fixtures are light fixtures,
such as neon lights or track lighting, which are decorative in nature and not necessary
for the operation of the building. If the decorative or task lighting were
turned off, the other sources of lighting would provide sufficient light for operation
of the building. If the decorative or task lighting is the primary
source of lighting, then it is section 1250 property.
|
1245
|
57.0 Distributive Trades and Services -
5 Years
|
|
Light Fixtures - Exterior
|
Exterior lighting is considered section 1250 property to the extent that the lighting
relates to the maintenance or operation of the building. This category includes
building mounted lighting to illuminate walkways, entrances, parking, etc.
(whether decorative or not).
|
1250
|
Building or Building Component –
39 Years
|
|
Pole mounted or freestanding outdoor lighting system to illuminate sidewalks,
Employee Parking Area, Customer Parking Area, and Product Display Parking Areas.
See also Poles.
Note* asset class 00.3 Land improvements includes both section 1245 and 1250
property per Rev. Proc. 87-56.
The Revenue Procedure establishes two broad categories of depreciable assets:
(1) asset classes 00.11 through 00.4 that consist of specific assets used in all
business activities; and (2) asset classes 01.1 through 80.0 that consist of assets
used in specific business activities. An asset described in both an asset and an
activity category is classified in the asset category.
|
See Note*
|
00.3 Land Improvements –
15 Years
|
|
Exterior lighting that highlights the merchandise and building exterior, for example
a floodlight, spotlight, and uplighting which do not illuminate parking areas or
walkways. Does not include the pole mounted lighting systems used to illuminate
Employee Parking Area, Customer Parking Area, and Product Display Parking Areas.
See also Poles.
|
1245
|
57.0 Distributive Trades and Services --
5 Years
|
|
Loading Docks
|
Includes bumpers, permanently installed dock levelers, plates, seals, lights, canopies,
and overhead doors used in the receiving and shipping of merchandise. See
also Awnings & Canopies.
|
1250
|
Building or Building Component –
39 Years
|
|
Includes equipment such as compactors, conveyors, hoists and balers.
|
1245
|
57.0 Distributive Trades and Services --
5 Years
|
|
Machinery & Equipment
|
Tangible personal property not covered elsewhere, which is in the nature of machinery
or equipment. Includes, for example, machinery and equipment located in the
Body Shop, Parts Department and Service Departments such as paint
booths; exhaust systems; air compressors; pneumatic tools systems (including support
equipment such as piping and related pumps); tanks and related pumps; automotive
fluid and waste fluid recovery systems; above-ground lifts; car wash systems, etc.
Does not include structural components of a building or other inherently permanent
structure. See also Concrete Foundation & Footings; Electrical;
and Plumbing.
|
1245
|
57.0 Distributive Trades and Services --
5 Years
|
Millwork
|
General millwork is all building materials made of finished wood (e.g., doors and
frames, window frames, sashes, porch work, mantels, panel work, stairways, and special
woodwork). Includes pre-built wooden items brought to the site for installation
and items constructed on site such as restroom cabinets, door jambs, moldings, trim,
etc.
|
1250
|
Building or Building Component –
39 Years
|
|
Decorative millwork is the decorative finish carpentry in the building. Examples
include detailed crown moldings, lattice work placed over finished walls or ceilings,
and merchandise display cabinets. The decorative millwork serves to enhance
the overall décor of the dealership and is not related to the operation of the building.
Cabinets and counters in the restroom are excluded from this category. See
also Cabinetry and Restroom Accessories.
|
1245
|
57.0 Distributive Trades and Services --
5 Years
|
|
Office – Furniture (includes Communication Equipment and Hook-ups)
|
Includes desks, chairs, cashiers safes, credenzas, file cabinets, tables (or other
furniture such as workstations and the Sales Manager’s office tower)
and shelving, including cost of shelves in record storage room. Also includes
telephone equipment, fax machines, and other communications equipment. Does
not include communications equipment included in other asset classes in Rev. Proc.
87-56.
|
1245
|
00.11 Office Furniture, Fixtures, and Equipment –
7 Years
|
|
Parking Lots
|
Depreciable improvements directly to or added to land, whether such improvements
are section 1245 or 1250. Grade level surface parking and base area usually
constructed of asphalt, brick, concrete, stone or similar material. Also includes
bumper blocks, curb cuts, curb work, striping, concrete landscape islands, gates,
fences, truck parking ramps and staging areas, and traffic control systems (such
as traffic lights and detectors, card readers, parking equipment, etc.). Includes
Employee Parking, Customer Parking, and New and Used Vehicle Parking
Areas.
Note* asset class 00.3 Land improvements includes both section 1245 and 1250
property per Rev. Proc. 87-56.
The Revenue Procedure establishes two broad categories of depreciable assets:
(1) asset classes 00.11 through 00.4 that consist of specific assets used in all
business activities; and (2) asset classes 01.1 through 80.0 that consist of assets
used in specific business activities. An asset described in both an asset and an
activity category is classified in the asset category.
|
See Note*
|
00.3 Land Improvements –
15 Years
|
|
Parking Structures
|
Any structure or edifice the purpose of which is to provide parking space.
Includes, for example, garages, parking ramps, or other parking structures.
|
1250
|
Building or Building Component –
39 Years
|
|
Plumbing
|
All piping, drains, sprinkler mains, valves, sprinkler heads, water flow switches,
restroom plumbing fixtures (e.g. toilets) and piping, sinks, electric water coolers,
and all other components of a building plumbing system (water or gas) not specifically
identified elsewhere. Includes floor drains which ultimately lead to the municipal
sewer system or site septic system.
|
1250
|
Building or Building Component –
39 Years
|
|
Special plumbing connections which are necessary to and used directly with a specific
item of machinery or equipment or connections between specific items of individual
machinery or equipment. Includes dedicated piping, valves, and hook-ups by
which machinery and equipment is connected to the building or other inherently permanent
structure's plumbing distribution system(s).
Example includes plumbing hook-ups to the car wash system. Does not include
plumbing hook-ups of general applicability and accessibility. See also Floor
Pits & Trenches.
|
1245
|
57.0 Distributive Trades and Services --
5 Years
|
|
Point of Sale (POS) Systems
|
A register or terminal based data collection system used to control and record all
sales (cash, charge, COD, gift cards, layaway, etc.) at the point of sale.
Includes cash registers, computerized sales systems and related peripheral equipment,
satellite systems, scanners, and wands. See also Electrical for hook-ups.
|
1245
|
57.0 Distributive Trades and Services --
5 Years
|
|
Poles
|
Light poles for parking areas and other poles poured in concrete footings or bolt-mounted
for signage, flags, etc. Note* asset class 00.3 Land improvements includes
both section 1245 and 1250 property per Rev. Proc. 87-56.
See also Bollards & Guardrails; Signs; and Light Fixtures – Exterior.
|
See Note*
|
00.3 Land Improvements –
15 Years
|
|
Premise (Pylon) Sign - Exterior
|
Pylons made of concrete, brick, wood frame, stucco, or similar materials usually
set in the ground or on a concrete foundation, and usually used for signage.
Note* asset class 00.3 Land improvements includes both section 1245 and 1250 property
per Rev. Proc. 87-56. See also Poles.
|
See Note*
|
00.3 Land Improvements –
15 Years
|
|
Includes only the sign face and/or message screen and related components.
Includes brand displays and dealership brand image enhancements.
|
1245
|
57.0 Distributive Trades and Services --
5 Years
|
|
Restroom Accessories
|
Includes paper towel dispensers, electric hand dryers, towel racks or holders, cup
dispensers, purse shelves, toilet paper holders, soap dispensers or holders, lotion
dispensers, sanitary napkin dispensers and waste receptacles, coat hooks, handrails,
grab bars, mirrors, shelves, vanity cabinets, counters, ashtrays, baby changing
stations, and other items generally found in public restrooms that are built into
or mounted on walls or partitions.
|
1250
|
Building or Building Component –
39 Years
|
|
Restroom Partitions
|
Includes shop made and standard manufacture toilet partitions, typically metal,
but may be plastic, sheetrock, wall board, or other materials.
|
1250
|
Building or Building Component –
39 Years
|
|
Retail Accessories
|
Accessories used to better display merchandise, advertising, and brochures that
are not held for sale. Includes assets such as audio/video display devices,
graphic rear projection displays, artwork (if depreciable), Showroom
displays, decorative mobile props, holiday decorations, lamps, mirrors, pictures,
plaques, potted plants, and props (such as sporting equipment or memorabilia, etc.).
Does not include non-depreciable art, antiques, or collectibles).
|
1245
|
57.0 Distributive Trades and Services --
5 Years
|
|
Retail
Fixtures
|
Includes assets such as the retail counter space within the Body Shop,
shelving to store parts and supplies, mechanical retrieval system or equipment for
parts and supplies, clocks, including time clocks, counter space related to the
Parts Department, including retail counter space and cashier, etc.,
shelving systems, shelf racks in the Service Department tool room,
counter space within the Service Department (including dispatcher
counter and parts counter for technicians) and other dealership fixtures needed
in the business operation that are not a building component. Also includes
fixtures and shelving for vehicle brand clothing and accessory Retail Shop,
children’s Play Area improvements for customers, fixtures for inventory
information centers, and express lube after care business fixtures.
|
1245
|
57.0 Distributive Trades and Services --
5 Years
|
|
Roof
|
All elements of the roof including but not limited to joists, rafters, deck, shingles,
vapor barrier, skylights, trusses, girders, and gutters. Determination of
whether decorative elements of a roof (e.g. false dormers, mansard) constitute structural
building components depends on their integration with the overall roof, not their
load bearing capacity. If removal of the decorative element results in the
direct exposure of building components to water, snow, wind, or moisture damage,
or if the decorative element houses lighting fixtures, wiring, or other structural
components, then the decorative elements are part of the overall roof system and
are structural components of the building.
|
1250
|
Building or Building Component –
39 Years
|
|
Security Systems
|
Includes security equipment for the protection of the building (and its contents)
from burglary or vandalism and protection of employees from assault. Examples
include window and door locks; card key access systems; keyless entry systems; security
cameras, recorders, monitors and related equipment; perimeter and interior building
motion detectors; security lighting; alarm systems; and security system wiring and
conduit.
|
1250
|
Building or Building Component -- 39 Years
|
|
Electronic surveillance systems used to track and monitor tangible items, e.g.,
devices used to protect New and Used automobile inventory. Includes scanners,
electronic gates, surveillance cameras, recorders, monitors and related equipment.
|
1245
|
57.0 Distributive Trades and Services --
5 Years
|
|
Sidewalks & Curbs
|
Depreciable improvements directly to or added to land, whether such improvements
are section 1245 or 1250. Sidewalks and curbs are usually constructed of concrete,
asphalt, stone or similar material. Note* asset class 00.3 Land improvements
includes both section 1245 and 1250 property per Rev. Proc. 87-56.
|
See Note*
|
00.3 Land Improvements –
15 Years
|
|
Signs
|
Exit signs, restroom identifiers, room numbers, and other signs relating to the
operation or maintenance of a building.
See also Exit Signs.
|
1250
|
Building or Building Component – 39 Years
|
|
Interior and exterior signs used to display brand or theme identity. For example,
interior signs to identify departments or exterior signs to display trade names
or trade symbols.
For pylon signs, includes only sign face. See also Poles and Premise
(Pylon) Sign - Exterior.
|
1245
|
57.0 Distributive Trades and Services --
5 Years
|
|
Site Preparation Grading & Excavation
|
In general, land preparation costs include the one time cost of clearing and grubbing,
site stripping, mucking, and fill or excavation to allow development of land.
Clearing and grubbing is the removal of debris, brush, trees, etc. from the site.
Stripping is the removal of the topsoil to provide a stable surface for site and
building improvements. Mucking is the removal of unstable soils and materials
to insure a solid base for intended improvements. The grading of land involves
moving soil for the purpose of producing a more level surface to allow development
of the land.
|
|
Land
|
|
Clearing, grading, excavating and removal costs directly associated with the construction
of buildings and building components are part of the cost of construction of the
building and depreciated over the life of the building. This includes building
the showroom facility on a mound foundation for higher visibility and enhanced visual
impact for the dealership building.
|
1250
|
Building or Building Component –
39 Years
|
|
Clearing, grading, excavating and removal costs directly associated with the construction
of sidewalks, parking areas, roadways and other depreciable land improvements are
part of the cost of construction of the improvements and depreciated over the life
of the associated asset. Note* asset class 00.3 Land improvements includes
both section 1245 and 1250 property per Rev. Proc. 87-56.
|
See Note*
|
00.3 Land Improvements –
15 Years
|
|
Site Utilities
|
Site utilities are the systems that are used to distribute utility services from
the property line to the building. Includes water, sanitary sewer, gas, electrical
services, and data and communication lines.
|
1250
|
Building or Building Component –
39 Years
|
|
Site Work
|
Site work includes curbing, paving, general site improvements, fencing, depreciable
landscaping, roads, sewers, sidewalks, site drainage and all other site improvements,
such as storm water retention basins, not directly related to the building.
See also Landscaping & Shrubbery. For sanitary sewers, see Site
Utilities. Does not include land preparation costs, see also Site Preparation
Grading & Excavation.
Note* asset class 00.3 Land improvements includes both section 1245 and 1250
property per Rev. Proc. 87-56.
|
See Note*
|
00.3 Land Improvements –
15 Years
|
|
Sound Systems
|
Equipment and apparatus, including wiring, used to provide amplified sound or music.
For example, public address by way of paging a customer or employee. Excludes
applications linked to fire protection and alarm systems.
|
1245
|
57.0 Distributive Trades and Services --
5 Years
|
|
Trash Enclosures
|
Enclosures for waste receptacles that are attached to the building. Typically
constructed of the same materials as the building shell with either interior or
exterior access. These trash enclosures are an integral part of the building
shell and cannot be moved without damage to the underlying building.
|
1250
|
Building or Building Component –
39 Years
|
|
Freestanding enclosures for waste receptacles, typically constructed on a concrete
pad with its posts set in the concrete. Serves both safety and decorative
functions. Note* asset class 00.3 Land improvements includes both section
1245 and 1250 property per Rev. Proc. 87-56.
|
See Note*
|
00.3 Land Improvements –
15 Years
|
|
Wall Coverings
|
Includes interior and exterior paint; ceramic or quarry tile, marble, stone, brick
and other finishes affixed with mortar, cement or grout; paneling, wainscoting and
other wood finishes affixed with nails, screws or permanent adhesives; and wall
panels such as fiberglass, stainless steel and plastic wall panels.
|
1250
|
Building or Building Component –
39 Years
|
|
Strippable wallpaper that causes no damage to the underlying wall or wall surface.
|
1245
|
57.0 Distributive Trades and Services --
5 Years
|
|
Walls - Exterior
|
Includes all exterior walls and building support regardless of construction materials.
Exterior walls may include columns, posts, beams, girders, curtain walls, tilt up
panels, studs, framing, sheetrock, insulation, windows, doors, exterior façade,
brick, masonry, etc. Also includes drive-through bay, windows, and doors.
|
1250
|
Building or Building Component –
39 Years
|
|
Walls - Interior Partitions
|
Includes all load bearing interior partitions regardless of construction.
Also includes non-load bearing partitions regardless of height (typically constructed
of studs and sheetrock or other materials) that divide or create rooms or provide
traffic control. Includes rough carpentry and plaster, dry wall or gypsum
board, and other finishes.
|
1250
|
Building or Building Component –
39 Years
|
|
Walls - Interior Partitions
|
Interior walls where the partition can be 1) readily removed and remain in substantially
the same condition after removal as before, or 2) intended to be moved and reused,
stored, or sold in their entirety.
|
1245
|
57.0 Distributive Trades and Services --
5 Years
|
|
Windows
|
Exterior windows, including store front windows, and exterior glass partitions.
Includes interior glass partitions from floor to ceiling or as a part of an interior
wall.
|
1250
|
Building or Building Component –
39 Years
|
|
Window Treatments
|
Window treatments such as drapes, curtains, louver, blinds, post construction tinting
and interior decorative theme décor which are readily removable.
|
1245
|
57.0 Distributive Trades and Services --
5 Years
|